2N Lift8 v1.0 User Manual
Page 68

68
981
Check call
0 - 5
0
0 = switched off
1 = switched on, first call
after 3 minutes and then
according to par 983
2 = switched on, first call
after 2 hours and then
according to par 983
3 = switched on, call
according to parameter
983
4 = switched on, call on
next day configured in
parameter 986
5 = switched on, first call
after 3 minutes and then
according to parameter
983
982
Interval of
check call
hhmmhhmm
00002359
Allows configuration of
announcement until time
of lower traffic (lower
tariff), generated at
random in time interval
983
Period of check
call
0 – 100 days
3 days
0 = switched off
(configuration par.981 to 0
has same effect), the
value is expressed if par
981 is configured to
1,2,3,5
986
Days in week
for check call
Mon, Tue, Wed,
Thur, Fri, Sat, Sun
empty
Values for Mon, Tue, Wed,
Thur, Fri, Sat, Sun:
0 = do not call
1 = call
p = Monday
ú = Tuesday
s = Wednesday
...n = Sunday
Example:
1000100 = check call will
be made on Monday and
Friday.
991
Servicing
password
max. 16 numerals 0
- 9
12345
Possibility of changing
default servicing password
992
Rescue
password
max. 16 numerals 0
- 9
empty
995
Permit for
calling from
machine room
0 - 1
0
0 = forbidden, 1 =
permitted (if the
parameter is permitted it
is possible for the machine
room to call via the
announcer to the public
network)