Configure POINT I/O Modules for DeviceNet Networks 207

For example, assume you have five POINT I/O modules in a line, and the address
of the first module is 10. After the Sequential Address command is sent to the
first module, the node address of the line is 10, 11, 12, 13, and 14.

Using Third-party Configuration Software

When using third-party configuration software, load the EDS files into the
software and follow the designers instructions.

Configure Digital Modules
Using RSNetWorx Software

To configure digital input modules, proceed as follows, noting that input
modules use dialogs similar to the one for the 1734-IB4 modules used in this
procedure.

1. Open your RSNetWorx for DeviceNet software.
2. Using the selections on the left, construct your system.

If your network is up, click Browse.

3. After setting up your system, double-click the module you want to

configure.

If you are online, upload the configuration.