Diagclearerror – Dell POWEREDGE M1000E User Manual

Page 235

Advertising
background image

Fabric OS Command Reference

203

53-1001764-02

diagClearError

2

diagClearError

Clears the diagnostics failure status.

Synopsis

diagclearerror [[--slot] slot] -all

Description

Use this command to clear the diagnostics failure status.

Note

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

Operands

This command has the following operand:

--

slot slot

Specify the slot on which to clear the diagnostics failure status. The default is
set to 0 and designed to operate on fixed-port-count products.

-all

If specified, all blades clear

.

If no operand is specified, the default is to clear all bad port flags.

Examples

To clear the diag software flag:

switch:admin>

diagclearerror 8

ERROR: DIAG CLEARERR

Diagnostics Errors Cleared, port: 8/31

Err# 0120041 081F

See Also

none