Dell POWEREDGE M1000E User Manual

Page 627

Advertising
background image

Fabric OS Command Reference

595

53-1001764-02

perfTTmon

2

Operands

This command has the following operands:

slot

For bladed systems only, specifies the slot number of the port on which to
install Top Talkers, followed by a slash (/).

port

Specifies the number of the port on which the Top Talker is to be installed,
relative to its slot for bladed systems. Use switchShow for a list of valid ports.

F_Port Top Talker commands:

--

add

Installs the Top Talker monitor on a specified F_Port.

egress | ingress

Used with the --add option to specify the direction in which the traffic is
monitored as incoming or outgoing. This operand is required.

--

show

Displays the top talking flows on a specified port.

number of top talking flows

Specifies "n" top talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and
a warning message. This operand is optional; if omitted, the command
displays the top 8 flows.

wwn | pid

Specifies the output display as either WWN or PID format. This operand is
optional. If omitted, the command displays in WWN format.

--

delete

Deletes an existing Top Talker monitor on a specified F_Port.

Fabric Mode Top Talker commands:

--

add fabricmode

Installs the Top Talker monitor on all switches in the fabric. When a new
switch joins the fabric, this command must be run again on the switch. The TT
configuration information is not propagated automatically to the new switch.

--

show

Displays the Top Talking flows on the switch for a given domain ID.

dom dom_id

Specifies the domain ID for the flow display.

number of top talking flows

Specifies "n" Top Talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and
a warning message. This operand is optional; if omitted, the command
displays the top 8 flows.

wwn | pid

Specifies display as either WWN or PID format. This operand is optional; if
omitted, the command displays in WWN format.

--

delete fabricmode

Deletes the Fabric Mode Top Talker.

Examples

To add an F_Port Top Talker to blade 1 port 2 (which should be an F_Port):

Switch:admin>

perfttmon --add ingress 1/2

To delete the F_Port Top Talker:

switch:admin>

perfttmon --del 1/2

Advertising