Portcfglosstov – Dell POWEREDGE M1000E User Manual

Page 686

Advertising
background image

654

Fabric OS Command Reference

53-1001764-02

portCfgLossTov

2

portCfgLossTov

Enables or disables de-bouncing of signal loss for front end ports.

Synopsis

portcfglosstov [slot]/port mode

Description

Use this command to enable or disable the de-bouncing of loss of signal for 100 ms for front end
ports. Use portCfgShow to display the current setting.

If executed without operands, the command prints the usage.

Notes

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

On a chassis, this command must be executed on the active CP.

Operands

This command has the following operands:

slot

For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).

port

Specifies the port to be configured, relative to its slot for bladed systems. Use
switchShow to list valid ports.

mode

Specify 1 to enable the configuration. Specify 0 to disable the configuration.

Examples

To enable the configuration on port 1/5 and to display the configuration:

switch:admin>

portcfglosstov 1/5 1

switch:admin>

portcfgshow 1/5

Area Number:

5

Speed Level: AUTO(HW)

Fill Word: 0(Idle-Idle)

AL_PA Offset 13: OFF

Trunk Port ON

Long Distance OFF

VC Link Init OFF

Locked L_Port OFF

Locked G_Port OFF

Disabled E_Port OFF

Locked E_Port OFF

ISL R_RDY Mode OFF

RSCN Suppressed OFF

Persistent Disable OFF

LOS TOV enable

ON

NPIV capability ON

QOS E_Port AE

Port Auto Disable: OFF

Rate Limit OFF

EX Port OFF

Credit Recovery ON

F_Port Buffers OFF

NPIV PP Limit: 126

CSCTL mode: OFF

Advertising