2

perfCfgRestore

Restores performance monitoring configuration settings from nonvolatile memory.

Synopsis

perfcfgrestore

Description

Use this command to restore the performance monitoring configuration information from
nonvolatile memory. This does not restore the information cleared by the perfCfgClear command;
rather, it restores the configuration from nonvolatile memory. The perfCfgRestore command
overwrites any configuration changes that were not saved.

Notes

This command requires an Advanced Performance Monitoring license.

This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and
GbE ports.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

Operands

none

Examples

To restore the performance monitoring configuration information from nonvolatile memory:

switch:admin>

perfcfgrestore

This will overwrite current Performance Monitoring settings

in RAM. Do you want to continue? (yes, y, no, n): [no]

y

Please wait ...

Performance monitoring configuration restored from FLASH.