Fabric OS Command Reference

253

53-1001764-02

fcipPathTest

2

5

Central ASIC FC loopback

7

SFP and central ASIC FC loopback

8

PHY and central ASIC FC loopback

9

FCIP FPGA GMAC and central ASIC FC loopback

-nframes count

Specifies the number of frames to send. The test progresses until the
specified number of frames are transmitted on each port. The default value is
100 (Brocade 7500/FR4-18i and Brocade 7800/FX8-24).

-length data_length

Specifies the data length of the frames used in the test (Brocade
7500/FR4-18i only). The default is 1,024; the maximum is 2,112 FC frames
and 8,196 data packets.

-compress mode

Specifies the compression device for which to select or to bypass data
compression for the test (Brocade 7500/FR4-18i only). By default, data
compression is used. This setting is applicable only to path mode 1 and 2.

Examples

To run the test on slot 2 with PHY loopback sending 10 frames:

switch:admin>

fcippathtest

--

slot 2 -path 2 -nframes 10

Running fcippathtest ..............

Test Complete: fcippathtest Pass 10 of 10

Duration 0 hr, 1 min & 50 sec (0:1:50:942).

passed.

Diagnostics

When it detects failures, the test may report one or more of the following error messages:

PATH_TEST_ERR

PATH_TEST_CHIP_INIT_ERR

PATH_TEST_IMAGE_ERR

PATH_TEST_TIMEOUT_ERR

PATH_TEST_HEARTBEAT_ERR

PATH_TEST_INVALID_RESULT

PATH_TEST_GE_PORT_ENABLE_ERR

PATH_TEST_GE_PORT_DISABLE_ERR

See Also

fcipChipTest

Advertising