Mstdenable – Dell POWEREDGE M1000E User Manual

Page 548

Advertising
background image

516

Fabric OS Command Reference

53-1001764-02

msTdEnable

2

msTdEnable

Enables the Management Server (MS) topology discovery service.

Synopsis

mstdenable ["ALL"]

Description

Use this command to enable the MS topology discovery service on the local switch or throughout
the fabric. The change takes effect immediately and commits to the configuration database for all
affected switches. The change is persistent across power cycles and reboots.

Notes

Topology Discovery Management requires the attached devices (including attached switches) to
support request node identification data (RNID) extended link service (ELS).

When an FCS policy is enabled, and this command is issued with the "ALL" operand, it can be
issued only from the primary FCS.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

This command is supported only in AD0 and AD255 contexts.

Operands

The following operand is optional:

"ALL"

Enables the MS topology discovery service throughout the fabric. This
operand must be enclosed in double quotation marks.

Examples

To enable the MS topology discovery service on the local switch:

switch:admin>

mstdenable

Request to enable MS Topology Discovery Service in progress....

done.

*MS Topology Discovery enabled locally.

To enable MS topology discovery on all switches in the fabric:

switch:admin>

mstdenable "ALL"

Request to enable MS Topology Discovery Service in progress....

done.

*MS Topology Discovery enabled locally.

*MS Topology Discovery Enable Operation Complete!!

See Also

msTdDisable, msTdReadConfig

Advertising