Fabric OS Command Reference

683

53-1001764-02

portCfgShow

2

To display FCIP parameters on the Brocade 7800 (with IPv6 support):

switch:admin>

portcfgshow ge2

Mode: FCIP

Persistent Disable: OFF

Ipif configuration:

Interface IP Address NetMask MTU

----------------------------------------------------

0 192.168.2.10 255.255.255.0 1500

1 192.168.2.12 255.255.255.0 1500

2 192.168.2.13 255.255.255.0 1500

3 192.168.2.11 255.255.255.0 1500

4 192.168.2.110 255.255.255.0 1500

Interface IPv6 Address Len MTU

--------------------------------------------------------

0 20::2:10 64 1500

Iproute Configuration:

IP Address Mask Gateway Metric

------------------------------------------------------

192.168.42.0 255.255.255.0 192.168.2.250 0

IPv6ddress Len Gateway Metric

-------------------------------------------------------

20:42:: 64 20::2:250 0

Vlantag configuration:

-------------------------

Interface Address VlanId L2CoS

Destination Address

------------------------------------------------------

192.168.2.10 200 5

0.0.0.0

192.168.2.10 300 5

192.168.2.21

To display the VLAN tagging configuration only:

switch:admin>

portcfgshow vlantag ge2

Port: ge2

Vlantag configuration:

-------------------------

Interface Address VlanId L2CoS

Destination Address

---------------------------------------------------

192.168.2.20 200 5

0.0.0.0

192.168.2.21 300 5

192.168.2.10