Diagretry – Dell POWEREDGE M1000E User Manual

Page 240

Advertising
background image

208

Fabric OS Command Reference

53-1001764-02

diagRetry

2

diagRetry

Sets or displays diagnostic retry mode.

Synopsis

diagretry [mode | -show]

Description

Use this command to enable retry mode if the mode value is nonzero and to disable the retry mode
if the mode value is 0. The mode is saved in flash memory (and stays in that mode) until the next
execution of diagRetry. The mode becomes active as soon as this command is executed; it does not
require a reboot to take effect.

Retry mode modifies the behavior of the diagnostic test methods, power-on self-test (POST), and
burn-in scripts. The exact behavior depends on the tests and scripts that are run.

Note

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

Operands

This command has the following optional operands:

mode

Specify 1 to enable, 0 to disable retry mode.

-show

Displays the current mode setting.

If no operand is specified, the current value is displayed.

Examples

To view and modify the current retry mode value:

switch:admin>

diagretry -show

Diagnostic Retry Mode is currently enabled.

switch:admin>

diagretry 0

Config update Succeeded

Diagnostic Retry Mode is now disabled.

switch:admin>

diagretry 1

Config update Succeeded

Diagnostic Retry Mode is now enabled.

See Also

none

Advertising