ADLINK PCI-8154 User Manual
Page 123
![background image](/manuals/733469/123/background.png)
MotionCreatorPro
113
1. Jog Type:
Z
Continuous Jog: Continuous Jog means that when you
press one directional button, the axis will continuously
move with an increasing speed. The longer you press,
the faster it runs. When you un-press the button, the axis
will stop immediately.
Z
Incremental Jog: Incremental jog means that when you
click one directional button, the axis will step a distance
according to the Step-Size’s setting.
2. Jog Setting: Set the parameters for single axis motion.
This parameter is meaningless if “Jog Mode” is
selected, since the velocity and moving distance is
decided by pulse input.
Z
Start Velocity: Set the start velocity of motion in units of
PPS.
Z
Maximum Velocity: Set the maximum velocity of motion
in units of PPS.
Z
Tacc: Set the acceleration time in units of second.