ADLINK PCI-8154 User Manual

Page 174

Advertising
background image

164

Function Library

Double, ByVal Ex As Double, ByVal Ey As

Double, ByVal PitchPos As Double, ByVal

CW_CCW As Integer, ByVal StrVel As Double,

ByVal MaxVel As Double, ByVal Tacc As

Double, ByVal Tdec As Double, ByVal SVacc As

Double, ByVal SVdec As Double) As Integer

@ Argument

card_id

: Specify the PCI-8154 card index. The card_id could be

decided by DIP switch (SW1) or depend on slot sequence.Please
refer to _8154_initial().

AxisNo

: Axis number designated to move or stop.

OffsetCx

: X-axis (first axis of target axes) offset to center

OffsetCy

: Y-axis (second axis of target axes) offset to center

OffsetEx

: X-axis (first axis of target axes) offset to end of arc

OffsetEy

: Y-axis offset to end of arc

PitchDist

: Z-axis specified relative distance to move

Cx

: X-axis (first axis of target axes) absoult position of center of

arc

Cy

: Y-axis (second axis of target axes) absoult position of center of

arc

Ex

: X-axis (first axis of target axes) absoult position of end of arc

Ey

: Y-axis (second axis of target axes) absoult position of end of

arc

PitchPos

: Z-axis specified absolute position to move

card_id Physical axis AxisNo

0

0

0

1

1

2

2

3

3

1

0

4

1

5

Advertising