Operation Theory

4.5.4

General purpose counter

The source of general purpose counter could be any of the follow-
ing:

1. Command position output – the same as a command

position counter

2. Feedback position input – the same as a feedback posi-

tion counter

3. Manual Pulser input – Default setting

4. Clock Ticks – Counter from a timer about 9.8MHz

4.5.5

Target position recorder

The target position recorder is used for providing target position
information. It is used in continuous motion because motion con-
troller need to know the previous motion command’s target posi-
tion and current motion command’s target position in order to
calculate relative pulses of current command then send results
into pre-register. Please check if the target position is the same
with current command position before continuous motion; espe-
cially after the home and stop functions.