ADLINK PCI-8154 User Manual
Page 181
Advertising
Function Library
171
@ Argument
AxisNo
: Axis number designated to move or stop.
Disable
: Disable pulser input.
Disable = 1, disable pulser
Disable = 0, enable pulser
Dist
: Specified relative distance to move (unit: pulse)
For example, if SpeedLimit is set to be 100pps, then the axis
can move at fastest 100pps, even the input pulser signal rate is
more then 100pps.
DivF
: Divide factor (1-2047)
Note: When 0 or 2048 is entered, the division circuit will be
OFF.
MultiF
: Multiplication factor (0-31)
InputMode
: Setting of manual pulse input mode from the PA and
PB pins
card_id Physical axis AxisNo
0
0
0
1
1
2
2
3
3
1
0
4
1
5
…
…
Value
Meaning
0
1X AB phase type pulse input
1
2X AB phase type pulse input
2
4X AB phase type pulse input
3
CW/CCW type pulse input