11 manual pulser motion – ADLINK PCI-8154 User Manual

Page 179

Advertising
background image

Function Library

169

6.11 Manual Pulser Motion

@ Name

_8154_disable_pulser_input

– Disable the pulser input

_8154_pulser_pmove

– Manual pulser p_move

_8154_pulser_vmove

– Manual pulser v_move

_8154_set_pulser_ratio

– Set manual pulser ratio for actual

output pulse rate

_8154_set_pulser_iptmode

– Set the input signal modes of

pulser

@ Description

_8154_disable_pulser_input

This function is used to set the pulser input disable or enable.

_8154_pulser_pmove

With this command, the axis begins to move according to the
manual pulse input. The axis will output one pulse when it
receives one manual pulse, until the
_8154_disable_pulser_input

function disables the

pulser or the output pulse number reaches the distance.

_8154_pulser_vmove

With this command, the axis begins to move according to the
manual pulse input. The axis will output one pulse when it
receives one manual pulse, until the
_8154_disable_pulser_input

function disables the

pulser.

_8154_set_pulser_ratio

Set manual pulse ratio for actual output pulse rate. The formula
for manual pulse output rate is:

Output Pulse Count = Input Pulser Count x (MultiF + 1) x DivF /
2048

The DivF = 1~2047 Divide Factor

The MultiF= 0~31 Multiplication Factor