Function Library
181
erc_logic
: Set the active logic for the ERC signal
erc_pulse_width
: Set the pulse width of the ERC signal
erc_mode
:
sd_logic
:
sd_latch
: Set the latch control for the SD signal
Value
Mmeaning
0
Negative logic
1
Positive logic
Value
Meaning
0
12
μ
s
1
102
μ
s
2
409
μ
s
3
1.6 ms
4
13 ms
5
52 ms
6
104 ms
7
Level output
Value
Meaning
0
Disable
1
Output ERC when stopped by EL, ALM, or EMG input
2
Output ERC when complete home return
3
Both 1 and 2
Value
Meaning
0
Negative logic
1
Positive logic
Value
Meaning
0
Do not latch
1
latch