3.3.3.2.2.1.6.- Error Packets

This function allows the H60 to carry out an analysis of the erroneous packages for a prolonged
period of time. This period can be defined by the user between 1 and 59 minutes. To change
these parameters see paragraph 3.3.3.2.2.1.6.1.

The values which appear on screen are the following:

Start: Time at which the analysis start.

UncPkts (Uncorrected Packets): Total number of erroneous packages found throughout

the actual period of analysis.

ActInt (Actual Interval): Number of errors found in the current period of analysis.

LastInt (Last Interval): Number of errors found in the previous analysis.

WorsInt (Worst Interval): Number of erroneous packages found at the worst viewing

interval.

W.I.Start (Worst Interval Start): Time when the worst viewing interval start.

TLock (Time Locked): How long it has been connected to the digital channel.

TErFree (Time Error Free): Time since the last error occurred.

N.Ulock (Number of Unlocks): Total number of times it has disconnected.

MxTUlock (Maximum Time Unlocked): Longest period of time disconnected in some of

the connections.

All the parameters can be restarted at any point. To do so, activate the restart function (see
paragraph 3.3.3.2.2.1.6.1
).

- Error packets -