Televes Serie H-60 User Manual

Page 92

Advertising
background image

92

TV Mode

3.3.3.2.1.4.1.- Line C/N line

This function allows one to change the line with which one synchronises the meter to, in order

to carry out the C/N line measurement. Use the

to switch between line 3 and line 25 and

confirm by pressing the

key.

- C/N Line -

3.3.3.2.1.5.-CTB/CSO

Enables measurement of intermodulation products ofsecond and third order. The measure
of CSO

can be done with the service

(TV signal in the channel to be

measured) both disabled and enabled.

In the event of measure with service, the meter will automatically synchronize with the TV signal
to be measured on an empty line, which may be selected in the parameter "Line with service".

However, the measure of CTB can only be made with the service disabled, because it
is a measurement made in the frequency of the video carrier of the TV signal.

The CSO measure is carried out in different frequencies (at different distances from the video
carrier) within the selected channel, which may be modified by the menu button "Offsets CSO".

01031052_002_EN:103130_00.qxd 10/07/2013 8:00 Página 92