Measures Config.

3.3.1.2.2.- Extra Burst

The selection of this option provides a power voltage increase of 1V for a voltage of 13V (14V)
and of 1.5V for a voltage of 18V (19.5V).

The extra burst is applicable both for terrestrial and satellite.

- Powering with Extra Burst -

3.3.1.2.3.- DiSEqC

The DiSEqC protocol enables working with up to 16 input multi-switches. For the purpose, and
with the meter on the

satellite band

, on the power menu one should enable the voltage and tone

corresponding to the required polarity and band of the satellite.

As well as the chosen polarity and band, the multi-switch should be provided with information
on the satellite we intend to work with (the multi-switches group the different polarities in groups

=> The equipment detects voltage in the coaxial cable. In this case, the message that

will appear is "

Vext

". This situation should be avoided.

=> When the equipment detects a short circuit, it emits a sound signal, and the

message appearing in this case is "

Short Circuit

".

=> When the power consumption exceeds the maximum value allowed, the

message appearing is "

Límit Exceeded

".

In the last two cases, the power is cut off, and automatic attempts at re-establishing it
are made every 3 seconds, approximately.