Televes Serie H-60 User Manual

Page 91

Advertising
background image

91

EN

3.3.3.2.1.3- C/N

On selecting this function, the Carrier/Noise ratio measurement will be selected. Noise
measurement is carried out automatically.

- C/N Measurement. Channel tuning -

If the

channel tuning

mode is used, the channel on whose carrier the level measurement is

being taken will appear. As mentioned in the measurement of the V/A ratio, if

frequency tuning

,

is used, the level measurement is made on the frequency tuned by the user, and will depend on
that frequency corresponding with the real carrier of the channel.

3.3.3.2.1.4- C/N line

dB Measurement that indicates the quality of the analogue image.

This measurement corresponds to the sound carrier relationship but synchronised to a specific
TV line (line 3 and line 25). By default the selected line is line 6, a line that corresponds to a test
line.

The user can select any of the TV signal´s active lines using the Line C/NL function (paragraph
3.3.3.2.1.4.1).

01031052_002_EN:103130_00.qxd 10/07/2013 8:00 Página 91