Pressing and holding down the

key (>1 sec) enables us to activate / deactivate this mode.

All the parameters which can be modified in the spectrum analyser continue to work for the top
trace. The Span, Reference Level, RBW etc, as well as the different measurements of this trace
can therefore be modified, in the same way as explained in the relevant paragraphs.

3.3.4.7.4.- SWEEP

This function enables one to chose from three types of sweep: normal, fast and accurate
sweep.

Do so use the

and press the

key to confirm.

3.3.4.7.5.- Trigger mode

This function enables the detection of pulsatory signals. To do so programme the trigger level,

which may vary between -10dBµV and 120dBµV, by using the

and the

key to confirm.

If the maximum level of the input signal is greater than that value a representation will appear
on the spectrum screen.

To deactivate this function, one can select the OFF mode from the same menu as the trigger
level.

- Trigger mode -