50

Measures Config.

- Macromeasure Options -

The Parameters to be configured:

- Outlet: There are three options. The equipment establishes an order for the execution of the

Macromeasure, stopping at the chosen option.

- Wide band: The Macromeasure executes all its associated memories.

- Ter/Sat: The Macromeasure first executes the terrestrial memory and then the

satellite memory.

- FM/Ter/Sat: The Macromeasure first executes the FM memory, then the terrestrial

one, and finally the satellite memory.

- Log Options: This option enables the selection of a previously created LOG or starting a new

one.

- New Log: Each time the Macromeasure is executed, the meter will create a new

Log to store the results (the measurements).

- Summary Log: The meter will store the results of the Macromeasure in the desired

Log.

- Edit Log Name: With this function, the user can change the name of the new LOG.

For the meter to start recording the measurements of Macromeasure execution, you should

press key

on the option “Execute Macromeasure".