Televes Serie H-60 User Manual

Page 160

Advertising
background image

160

General

Before starting the cleaning process, make sure you have the following at hand:

– Isopropyl alcohol or a cleaning solvent specifically formulated to clean optical

connectors.

– Cleaning Wipes.

– Cleaning swabs.

– Optical fibre cleaning polyester tape.

– It is highly recommended to have an optical fibre inspection microscope.

Cleaning connectors/couplings:

Follow these steps:

- Remove the connector protective cap.

- Use a microscope to inspect fibre condition. If the fibre only needs cleaning, you can

continue with the cleaning process, otherwise dispose of the fibre.

- Use a cleaning swab specifically designed to clean optical connectors. Do not touch

the cleaning tip. Swabs are single use only. Do not reuse.

- Moisten the swab with isopropyl alcohol or a cleaning solvent specifically formulated to

clean optical connectors.

- Carefully insert the cleaning swab into the connector and gently rotate clockwise.

- Remove the swab from the connector.

- Insert a new dry cleaning swab in the connector and then rotate carefully.

- Use the microscope to check the cleaning job.

CAUTION. As with any other maintenance tasks, before cleaning the connectors,
you should make sure the equipment is off.

WARNING

01031052_002_EN:103130_00.qxd 10/07/2013 8:01 Página 160