2 velocity direct – BECKHOFF EL7037 User Manual

Page 125

Advertising
background image

Commissioning

Velocity
direct

Position
contr.

Extended
velocity
mode

Extended
position
mode

Velocity
sensor-
less

Load an-
gle
recog-
nition

Step loss recogni-
tion

with en-
coder

with en-
coder

Index
8010:03
Nominal
voltage

X

x

x

x

x

x

x

x

Index
8010:04
Motor
coil
resistanc
e

x

x

Index
8010:05
Motor
EMF

x

x

x

Index
8010:0A
Motor coil
inductanc
e

x

x

x

Index
8011:01
Kp factor
(curr.)

x

x

x

x

x

x

x

x

Index
8011:02
KI factor
(curr.)

x

x

x

x

x

x

x

x

Index
8014:01
Feed
forward
(pos.)

x

x

Index
8014:02
Kp factor
(pos.)

x

x

Index
8014:03
Kp factor
(velo.)

x

x

x

Index
8014:04
Tn (velo.)

x

x

x

Overview of parameter settings for individual operating modes

5.4.2

Velocity direct

In Velocity direct mode, the EL70x7 operates in the cyclic velocity interface. A defined velocity can be set via
the STM Velocity variable.

Prerequisites

• This mode can be used with a connected encoder or with the internal counter (without encoder).

EL70x7

125

Version 1.0

Advertising
This manual is related to the following products: