BECKHOFF EL7037 User Manual

Page 157

Advertising
background image

Configuration by means of the TwinCAT System Manager

Index 8012 STM Features Ch.1 (part 1)

Index

Name

Meaning

Data type

Flags

Default value

8012:0

STM Features
Ch.1

Maximum subindex

UINT8

RO

0x3A (58

dec

)

8012:01

Operation mode

permitted values:

BIT4

RW

0x00 (0

dec

)

0: Automatic

1: Velocity direct

3: Position controller

4: Ext. Velocity mode

5: Ext. Position mode

6: Velocity sensorless

8012:05

Speed range

permitted values:

BIT3

RW

0x01 (1

dec

)

0: 1000 Fullsteps/sec

1: 2000 Fullsteps/sec

2: 4000 Fullsteps/sec

3: 8000 Fullsteps/sec

4: 16000 Fullsteps/sec

5: 32000 Fullsteps/sec

8012:08

Feedback type

permitted values:

BIT1

RW

0x01 (1

dec

)

0: Encoder

1: Internal counter

8012:09

Invert motor polar-
ity

Invert the direction of rotation of the motor

BOOLEAN

RW

0x00 (0

dec

)

8012:0A

Error on step lost

Error on loss of step

BOOLEAN

RW

0x00 (0

dec

)

8012:11

Select info data 1 permitted values:

UINT8

RW

0x0B (11

dec

)

0: Status word

7: Motor velocity

11: Motor load

13: Motor dc current

101: Internal temperature

103: Control voltage

104: Motor supply voltage

150: Drive - Status word

151: Drive – State

152: Drive - Position lag (low word)

153: Drive - Position lag (high word)

Index 8012 STM Features Ch.1 (part 2)

Index

Name

Meaning

Data type

Flags

Default value

8012:19

Select info data 2

permitted values:

UINT8

RW

0x0D (13

dec

)

0: Status word

7: Motor velocity

11: Motor load

13: Motor dc current

101: Internal temperature

103: Control voltage

104: Motor supply voltage

150: Drive - Status word

151: Drive - State

152: Drive - Position lag (low word)

153: Drive - Position lag (high word)

8012:30

Invert digital input
1

Invert digital input

BOOLEAN

RW

0x00 (0

dec

)

8012:31

Invert digital input
2

Invert digital input

BOOLEAN

RW

0x00 (0

dec

)