BECKHOFF EL7037 User Manual

Page 97

Advertising
background image

Commissioning

Fig. 105: Default target state in the Slave

Manual Control

There are particular reasons why it may be appropriate to control the states from the application/task/PLC.
For instance:

• for diagnostic reasons

• to induce a controlled restart of axes

• because a change in the times involved in starting is desirable

In that case it is appropriate in the PLC application to use the PLC function blocks from the TcEtherCAT.lib,
which is available as standard, and to work through the states in a controlled manner using, for instance,
FB_EcSetMasterState.

It is then useful to put the settings in the EtherCAT Master to INIT for master and slave.

Fig. 106: PLC function blocks

EL70x7

97

Version 1.0

Advertising