185] is, The motor control is blocked (index 6010:02, The motor control is activated (index 6010:02 – BECKHOFF EL7037 User Manual

Page 185: 0x6000:01, 185] - latch c valid, 0x6000:02, 185] - latch extern valid, 0x6000:03, 185] - set counter done, 0x6000:04

Advertising
background image

Configuration by means of the TwinCAT System Manager

Input data

Index 6000 ENC Inputs Ch.1

Index

Name

Meaning

Data type

Flags

Default value

6000:0

ENC Inputs Ch.1

Maximum subindex

UINT8

RO

0x16 (22

dec

)

6000:01

Latch C valid

The counter value was latched with the C track.

BOOLEAN

RO

0x00 (0

dec

)

6000:02

Latch extern valid The counter value was stored via the external latch.

BOOLEAN

RO

0x00 (0

dec

)

6000:03

Set counter done

The counter was set.

BOOLEAN

RO

0x00 (0

dec

)

6000:04

Counter underflow Counter underflow.

BOOLEAN

RO

0x00 (0

dec

)

6000:05

Counter overflow

Counter overflow.

BOOLEAN

RO

0x00 (0

dec

)

6000:08

Extrapolation stall The extrapolated part of the counter is invalid

BOOLEAN

RO

0x00 (0

dec

)

6000:09

Status of input A

Status of the A-input.

BOOLEAN

RO

0x00 (0

dec

)

6000:0A

Status of input B

Status of the B-input.

BOOLEAN

RO

0x00 (0

dec

)

6000:0B

Status of input C

Status of the C-input.

BOOLEAN

RO

0x00 (0

dec

)

6000:0D

Status of extern
latch

Status of the ext. latch input.

BOOLEAN

RO

0x00 (0

dec

)

6000:0E

Sync error

The Sync error bit is only required for DC mode. It indi-
cates whether a synchronization error has occurred dur-
ing the previous cycle.

BOOLEAN

RO

0x00 (0

dec

)

6000:10

TxPDO Toggle

The TxPDO toggle is toggled by the slave when the data
of the associated TxPDO is updated.

BOOLEAN

RO

0x00 (0

dec

)

6000:11

Counter value

The counter value.

UINT32

RO

0x00000000 (0

dec

)

6000:12

Latch value

The latch value.

UINT32

RO

0x00000000 (0

dec

)

6000:16

Timestamp

Time stamp of the last counter change.

UINT32

RO

0x00000000 (0

dec

)

Index 6010 STM Inputs Ch.1

Index

Name

Meaning

Data type

Flags

Default value

6010:0

STM Inputs Ch.1

Maximum subindex

UINT8

RO

0x15 (21

dec

)

6010:01

Ready to enable

Driver stage is ready for enabling

BOOLEAN

RO

0x00 (0

dec

)

6010:02

Ready

Driver stage is ready for operation

BOOLEAN

RO

0x00 (0

dec

)

6010:03

Warning

a warning has occurred (see index A010 [

}

 188]

BOOLEAN

RO

0x00 (0

dec

)

6010:04

Error

an error has occurred (see index A010 [

}

 188]))

BOOLEAN

RO

0x00 (0

dec

)

6010:05

Moving positive

Driver stage is activated in positive direction

BOOLEAN

RO

0x00 (0

dec

)

6010:06

Moving negative

Driver stage is activated in negative direction

BOOLEAN

RO

0x00 (0

dec

)

6010:07

Torque reduced

Reduced torque is active

BOOLEAN

RO

0x00 (0

dec

)

6010:08

Motor stall

A loss of step has occurred

BOOLEAN

RO

0x00 (0

dec

)

6010:0C

Digital input 1

Digital input 1

BOOLEAN

RO

0x00 (0

dec

)

6010:0D

Digital input 2

Digital input 2

BOOLEAN

RO

0x00 (0

dec

)

6010:0E

Sync error

The Sync error bit is only required for DC mode. It indi-
cates whether a synchronization error has occurred dur-
ing the previous cycle.

BOOLEAN

RO

0x00 (0

dec

)

6010:10

TxPDO Toggle

The TxPDO toggle is toggled by the slave when the data
of the associated TxPDO is updated.

BOOLEAN

RO

0x00 (0

dec

)

6010:11

Info data 1

Synchronous information (selection via subindex 8012:11
[

}

 181])

UINT16

RO

0x0000 (0

dec

)

6010:12

Info data 2

Synchronous information (selection via subindex 8012:19
[

}

 181])

UINT16

RO

0x0000 (0

dec

)

6010:13

Motor load

Current motor load
Unit: 0.01°

INT16

RO

0x0000 (0

dec

)

6010:14

Internal position

Internal microstep position

UINT32

RO

0x00000000 (0

dec

)

6010:15

External position

Encoder position

UINT32

RO

0x00000000 (0

dec

)

EL70x7

185

Version 1.0