5 extended position mode – BECKHOFF EL7037 User Manual

Page 134

Advertising
background image

Commissioning

Fig. 152: Entering the velocity

5.4.5

Extended Position mode

In Extended Position mode the EL70x7 operates in the cyclic position interface with field-oriented control. A
defined position can be set via the STM Position variable.

Notes

• This operating mode can be only be used when an encoder with sufficiently high resolution (min. 4000

[INC/360°]) is connected.

• Only stepper motors from Beckhoff (AS10xx) are supported.

• TwinCAT NC is required.

• When this mode is enabled commutation determination is required, since the shaft requires a degree of

clearance. To this end the shaft moves a few degrees right and left.

Step by Step

• Add the terminal to the configuration as described in the section TwinCAT configuration settings –

manual [

}

 66] or – Online scan [

}

 72].

• Link the terminal with the NC as described in section Integration into the NC configuration [

}

 104] (if

TwinCAT NC is used).

• Configure the EL70x7

automatically - import the XML motor file into the startup directory as described in section Set-

tings in the CoE - automatic [

}

 105].

◦ manually - configure the parameters as described in section Settings in the CoE - manual

[

}

 105].

Set the operating mode in the CoE directory to Ext. Position mode [

}

 181], Fig. "Ext. Position mode".

EL70x7

134

Version 1.0

Advertising