To this end set the index 8010:01, 180] "nominal voltage" in the, Can be set in index 8010:02 – BECKHOFF EL7037 User Manual

Page 180

Advertising
background image

Configuration by means of the TwinCAT System Manager

Index 8000 ENC Settings Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8000:0

ENC Settings
Ch.1

Maximum subindex

UINT8

RO

0x0E (14

dec

)

8000:08

Disable filter

Deactivates the input filters.

BOOLEAN

RW

0x00 (0

dec

)

8000:0A

Enable micro in-
crements

The lower 8 bits of the counter value are extrapolated.

BOOLEAN

RW

0x00 (0

dec

)

8000:0E

Reversion of rota-
tion

Activates reversion of rotation of the encoder.

BOOLEAN

RW

0x00 (0

dec

)

Index 8010 STM Motor Settings Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8010:0

STM Motor Set-
tings Ch.1

Maximum subindex

UINT8

RO

0x0A (10

dec

)

8010:01

Maximal current

Maximum permanent motor coil current
Unit: 1 mA

UINT16

RW

0x1388 (5000

dec

)

8010:02

Reduced current

Reduced coil current
Unit: 1 mA

UINT16

RW

0x09C4 (2500

dec

)

8010:03

Nominal voltage

Nominal voltage (supply voltage) of the motor
Unit: 10 mV

UINT16

RW

0x1388 (5000

dec

)

8010:04

Motor coil resis-
tance

Internal resistance of the motor
Unit: 10 mOhm

UINT16

RW

0x0064 (100

dec

)

8010:05

Motor EMF

Countervoltage of the motor
Unit: 1 mV / (rad/s)

UINT16

RW

0x0000 (0

dec

)

8010:06

Motor fullsteps

Number of full motor steps

UINT16

RW

0x00C8 (200

dec

)

8010:07

Encoder incre-
ments (4-fold)

Number of encoder increments per revolution with
quadruple evaluation

UINT16

RW

0x1000 (4096

dec

)

8010:09

Start velocity

Minimum starting velocity of the motor
Unit: 10000 corresponds to 100% [

}

 126]

UINT16

RW

0x0000 (0

dec

)

8010:0A

Motor coil induc-
tance

Inductance of the motor
Unit: 0.01 mH

UINT16

RW

0x0000 (0

dec

)

8010:10

Drive on delay
time

Delay between activation of driver stage and
„ready = 1“

UINT16

RW

0x0064 (100dez)

8010:11

Drive off delay
time

Delay between deactivation of driver stage and
„ready = 0“

UINT16

RW

0x0096 (150dez)

Index 8011 STM Controller Settings Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8011:0

STM Controller
Settings Ch.1

Maximum subindex

UINT8

RO

0x02 (2

dec

)

8011:01

Kp factor (curr.)

Kp control factor of the current controller

UINT16

RW

0x0096 (150

dec

)

8011:02

Ki factor (curr.)

Ki control factor of the current controller

UINT16

RW

0x000A (10

dec

)

EL70x7

180

Version 1.0

Advertising
This manual is related to the following products: