Manufacturer configuration data (device-specific), Information / diagnostic data (device-specific), Index a020 pos diag data ch.1 – BECKHOFF EL7037 User Manual

Page 189: Index f010 module list, Index f081 download revision

Advertising
background image

Configuration by means of the TwinCAT System Manager

Index A020 POS Diag data Ch.1

Index

Name

Meaning

Data type

Flags

Default value

A020:0

POS Diag data
Ch.1

Maximum subindex

UINT8

RO

0x06 (6

dec

)

A020:01

Command re-
jected

Travel command was rejected

BOOLEAN

RO

0x00 (0

dec

)

A020:02

Command
aborted

Travel command was aborted

BOOLEAN

RO

0x00 (0

dec

)

A020:03

Target overrun

Target position was overrun in the opposite direction

BOOLEAN

RO

0x00 (0

dec

)

A020:04

Target timeout

The target window was not reached within the in-target
timeout

BOOLEAN

RO

0x00 (0

dec

)

A020:05

Position lag

The maximum following error was exceeded

BOOLEAN

RO

0x00 (0

dec

)

A020:06

Emergency Stop

An emergency stop was triggered (automatic or manual) BOOLEAN

RO

0x00 (0

dec

)

Manufacturer configuration data (device-specific)

Index F80F STM Vendor data

Index

Name

Meaning

Data type

Flags

Default value

F80F:0

STM Vendor data Maximum subindex

UINT8

RO

0x05 (5

dec

)

F80F:04

Warning tempera-
ture

Temperature warning threshold
Unit: 1 °C

INT8

RW

0x50 (80

dec

)

F80F:05

Switch off temper-
ature

Switch-off temperature
Unit: 1 °C

INT8

RW

0x64 (100

dec

)

Information / diagnostic data (device-specific)

Index F900 STM Info data

Index

Name

Meaning

Data type

Flags

Default value

F900:0

STM Info data

Maximum subindex

UINT8

RO

0x06 (6

dec

)

F900:01

Software version
(driver)

Software version of the output driver

STRING

RO

F900:02

Internal tempera-
ture

Internal terminal temperature
Unit: 1 °C

INT8

RO

0x00 (0

dec

)

F900:04

Control voltage

Control voltage
Unit: 1 mV, 10 mV with field-oriented control

UINT16

RO

0x0000 (0

dec

)

F900:05

Motor supply volt-
age

Motor supply voltage
Unit: 1 mV, 10 mV with field-oriented control

UINT16

RO

0x0000 (0

dec

)

F900:06

Cycle time

Current EtherCAT cycle time
Unit: 1 µs

UINT16

RO

0x0000 (0

dec

)

Index F010 Module list

Index

Name

Meaning

Data type

Flags

Default value

F010:0

Module list

Maximum subindex

UINT8

RW

0x03 (3

dec

)

F010:01

SubIndex 001

Encoder profile number

UINT32

RW

0x000001FF
(511

dec

)

F010:02

SubIndex 002

Stepper motor profile number

UINT32

RW

0x000002BF
(703

dec

)

F010:03

SubIndex 003

Positioning interface profile number

UINT32

RW

0x000002C0
(704

dec

)

Index F081 Download revision

Index

Name

Meaning

Data type

Flags

Default value

F081:0

Download revision Maximum subindex

UINT8

RO

0x01 (1

dec

)

F081:01

Revision number

Revision number

UINT32

RW

0x00000000 (0

dec

)

EL70x7