BECKHOFF EL7037 User Manual

Page 207

Advertising
background image

Error correction

Text ID Type

Place

Text (English
only)

Cause

0x82FF Error

Communicatio
n

Boot mode not activated

0x8300

Error

Encoder

Error while setting the position

0x8301

Error

Encoder

Encoder increments not configured

0x8302

Error

Encoder

Feedback-Error

The amplitude of the resolver is too small

0x8400

Error

Drive

Drive incorrectly configured

0x8401

Error

Drive

Limitation of the calibration velocity

0x8402

Error

Drive

Emergency stop activated

0x8403

Error

Drive

ADC Error

Error during current measurement in the
ADC

0x8404

Error

Drive

Overcurrent

Overcurrent in phase U, V or W

0x8405

Error

Drive

Modulo position invalid

0x8406

Error

Drive

DC-Link
undervoltage
(Error)

The DC link voltage of the terminal is lower
than the parameterised minimum voltage.
Activation of the output stage is prevented

0x8407

Error

Drive

DC-Link
overvoltage (Error)

The DC link voltage of the terminal is higher
than the parameterised maximum voltage.
Activation of the output stage is prevented

0x8408

Error

Drive

I2T-Model Amplifier
overload (Error)

- The amplifier is being operated outside the
specification
- The I2T-model of the amplifier is
incorrectly parameterised

0x8409

Error

Drive

I2T-Model motor
overload (Error)

- The motor is being operated outside the
parameterised rated values
- The I2T-model of the motor is incorrectly
parameterised

0x8415

Error

Drive

Modulo factor invalid

EL70x7

207

Version 1.0

Advertising