Configuration by means of the TwinCAT System Manager

Index

Name

Meaning

Data type

Flags

Default value

8012:32

Function for input
1

permitted values:

BIT4

RW

0x00 (0

dec

)

0: Normal input

1: Hardware enable

2: PLC cam

8012:36

Function for input
2

permitted values:

BIT4

RW

0x00 (0

dec

)

0: Normal input

1: Hardware enable

2: PLC cam

8012:3A

Function for output
1

permitted values:

BIT4

RW

0x0F (15

dec

)

0: Normal output

1: Break (linked with driver enable)

15: Disabled

Index 8014 STM Controller Settings 3 Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8014:0

STM Controller
Settings 3 Ch.1

Maximum subindex

UINT8

RO

0x09 (9

dec

)

8014:01

Feed forward
(pos.)

Pilot control of the position controller

UINT32

RW

0x000186A0
(100000

dec

)

8014:02

Kp factor (pos.)

Kp control factor of the position controller

UINT16

RW

0x01F4 (500

dec

)

8014:03

Kp factor (velo.)

Kp control factor of the velocity controller
Unit: 0.1 mA / (rad/s)

UINT32

RW

0x00000032
(50

dec

)

8014:04

Tn (velo.)

Time constant Tn of the velocity controller
Unit: 0.01 ms

UINT16

RW

0xC350 (50000

dec

)

8014:05

Sensorless param
1

First parameter (sensorless control)

UINT16

RW

0x0000 (0

dec

)

8014:06

Sensorless param
2

Second parameter (sensorless control)

UINT16

RW

0x0000 (0

dec

)

8014:07

Cross over veloc-
ity 1

First velocity transition (sensorless control)
Unit: 0.1 rad/s

UINT16

RW

0x0000 (0

dec

)

8014:08

Cross over veloc-
ity 2

Second velocity transition (sensorless control)
Unit: 0.1 rad/s

UINT16

RW

0x0000 (0

dec

)

8014:09

Cross over veloc-
ity 3

Third velocity transition (sensorless control)
Unit: 0.1 rad/s

UINT16

RW

0x0000 (0

dec

)

EL70x7

158

Version 1.0