Commissioning

• The process data can be transferred with TwinCAT NC or directly from the PLC.

Step by Step

• Add the terminal to the configuration as described in the section TwinCAT configuration settings –

manual [

}

 66] or – Online scan [

}

 72].

• Link the terminal with the NC as described in section Integration into the NC configuration [

}

 104] (if

TwinCAT NC is used).

• Configure the EL70x7

automatically - import the XML motor file into the startup directory as described in section Set-

tings in the CoE - automatic [

}

 105].

◦ manually - configure the parameters as described in section Settings in the CoE - manual

[

}

 105].

Set the operating mode in the CoE directory to Velocity direct [

}

 181], Fig. "Velocity direct mode".

Fig. 138: Velocity direct mode

• Under Predefined PDO Assignments [

}

 103] select Velocity control, Velocity control compact or Velocity

control compact with info data, Fig. "Predefined PDO Assignment: Velocity control compact".

Fig. 139: Predefined PDO Assignment: Velocity control compact

• Activate the configuration (Ctrl+Shift+F4).

• Run through the State Machine of the terminal. Here you have two options.

EL70x7

126

Version 1.0