Physical installation 1 - 6 – Yaskawa P7B Drive Bypass User Manual

Page 18

Advertising
background image

Physical Installation 1 - 6

Table 1.4 480V Enclosure Data

Input
Volts

HP

1

Drive

Model

CIMR-

Bypass

2

Model

Number

NEC

FLA

OL

110%
1 min

Heat

3

Loss

Watts

Enclosure Dimensions

4

NEMA 1 & NEMA 12 -FVFF

H W D

inches

Weight

5

of

Assembly

Enclosure Dimensions w/Add-on

4

NEMA 1 & NEMA 12-FVFF

H W D

inches

Weight

5

of

Assembly

+Add-on

Box

Electrical

Schematic

480

0.5

P7U42P21A

P7B_B001

1.1

1.2

57

29.48 19.06 13.66

Dimension Drawing

6

S-5542

115 lbs

43.35 19.06 13.66

Dimension Drawing

S-5543

156 lbs

P7B-00

0.75

P7U42P21A

P7B_B001

1.6

1.8

57

1

P7U42P21A

P7B_B002

2.1

2.3

62

2

P7U42P21A

P7B_B003

3.4

3.7

89

3

P7U42P21A

P7B_B004

4.8

5.3

121

5

P7U43P71A

P7B_B007

7.6

8.4

155

7.5

P7U45P51A

P7B_B011

11.0

12.1

217

10

P7U47P51A

P7B_B014

14.0

15.4

318

127 lbs

164 lbs

15

P7U40111A

P7B_B021

21.0

23.1

404

20

P7U40111A

P7B_B027

27.0

29.7

408

142 lbs

189 lbs

25

P7U40151A

P7B_B034

34.0

37.4

485

30

P7U40181A

P7B_B040

40.0

44.0

618

40

P7U40301A

P7B_B052

52.0

57.2

1040

40.48 25.63 14.66

Dimension Drawing

7

S-5544

203 lbs

55.35 25.63 14.66

Dimension Drawing

S-5545

281 lbs

50

P7U40301A

P7B_B065

65.0

71.5

1045

232 lbs

319 lbs

60

P7U40371A

P7B_B077

77.0

84.7

1197

75

P7U40451A

P7B_B096

96.0

105.6

1357

241 lbs

332 lbs

100

P7U40551A

P7B_B124

124.0

136.4

1749

125

P7U40750A

P7B_B156

156.0

171.6

2032

84.00 25.63 26.25

8

Dimension Drawing

9

S-5550

943 lbs

NOT REQUIRED

150

P7U40900A

P7B_B180

180.0

198.0

2486

200

P7U41100A

P7B_B240

240.0

264.0

2955

1240 lbs

250

P7U41600A

P7B_B302

302.0

332.2

4225

1352 lbs

300

P7U41850A

P7B_B361

361.0

397.1

4425

TBD

TBD

350

P7U41850A

P7B_B414

414.0

455.4

4451

400

P7U42200A

P7B_B477

477.0

524.7

5099

450

P7U42200A

P7B_B515

515.0

566.5

5154

500

P7U43000A

P7B_B590

590.0

649.0

7329

Note 1: Horsepower rating is based on a standard NEMA B 4-pole motor.

Note 2: The underscore position in these model numbers codes for the enclosure type: V = NEMA1, B = NEMA12 FVFF.

Note 3: Heat loss is the amount of heat dissipated by the drive at full load with all standard options available inside the enclosure. Drive heat sink losses are

included in the heat loss data. Heat loss data is for the enclosure without the add-on enclosure.

Note 4: Height dimension (H) excludes the mounting screw tabs. Depth dimension (D) excludes MCP disconnect handle.

Note 5: This data represents the total weight with all possible standard options. Weight could be less depending on the options specified.

Note 6: All standard options are available in this size enclosure except options E (RFI Filter) and K (5% Output Reactor). Options E and K require the

add-on enclosure.

Note 7: All options are available in this size enclosure except E (RFI Filter), R (3% Line Reactor), and K (5% Output Reactor). Only option E combined with

either option R or option K can be installed in the add-on enclosure. Options R and K together require an increase in the size of the P7 Bypass Enclosure.
Contact the factory if all three options are required. Options D (2 Motor “OR”) or A (2 Motor “AND”) for 75 Hp and 100 Hp require the next
size enclosure.

Note 8: Heat sink mounted externally varies the depth dimension depending on the drive size. Depth will not exceed dimension shown.

Note 9: All options are available in this size enclosure except options D (2 Motor “OR”) or A (2 Motor “AND”) for 200 Hp and 250 Hp require the next

size enclosure.

Advertising