Parameters A - 27

Monitor

U1-13

Cumulative Operation Time
Elapsed Time

Displays total operating or power-on time of the Drive.

U1-14

Software Number
FLASH ID

Displays Drive's software number.

U1-15

Terminal A1 Input Voltage
Term A1 Level

Displays the input voltage on Terminal A1, as a percentage of
10V DC.

U1-16

Terminal A2 Input Voltage
Term A2 level

Displays the input current (or voltage) on Terminal A2, as a
percentage of 20mA (or 10 V DC).

U1-18

Motor Secondary Current (I

q

)

Mot SEC Current

Displays the amount of current being used by the motor to
produce torque (Iq).

U1-20

Output Frequency After Soft Start
SFS Output

Displays the frequency reference (speed command) after the
accel and decel ramps.

U1-24

PI Feedback Value
PI Feedback

Displays the feedback signal when PI control is used.

U1-28

CPU Number
CPU ID

Displays control board hardware revision.

U1-29

kWh
kWh Lo 4 Digits

Displays the accumulated kWh.

U1-30

MWh
kWh Hi 5 Digits

Displays the accumulated MWh.

U1-34

First Parameter Causing an OPE
OPE Detected

Displays the parameter number causing an "OPE" fault.

U1-36

PI Input
PI Input

Displays the "error" in the PI regulator. (U1-36 = PI Setpoint -
PI Feedback).

U1-37

PI Output
PI Output

Displays the output of the PI as a percentage of maximum
frequency (E1-04).

U1-38

PI Setpoint
PI Setpoint

Displays the setpoint of the PI regulator (U1-38 = PI reference
+ PI bias).

U1-39

Memobus Communication Error
Code
Transmit Err

U1-40

Heatsink Cooling Fan Operation
Time
FAN Elapsed Time

Displays total operating time of the heatsink cooling fan.

U1-51

Auto Mode Frequency Reference
Value
Auto Mode Fref

Displays the frequency reference (speed command) when in
auto mode.

U1-52

Hand Mode Frequency Reference
Value
HAND Mode Fref

Displays the frequency reference (speed command) when in
hand mode, or displays Terminal A2 when differential mode is
selected.

U1-53

PI Feedback 2 Value
PI Feedback 2

Displays PI feedback 2 value.

Table 2: Monitor List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

1: CRC error

1: Data length error

Not used. Always 0.

1: Parity error

1: Overrun error

1: Fleming error

1: Timeover

Not used. Always 0

.

0 0 0 0 0 0 0 0