Electrical installation 2 - 21 – Yaskawa P7B Drive Bypass User Manual

Page 59

Advertising
background image

Electrical Installation 2 - 21

(61)

(62)

(61)

(62)

(A2)

(A1)

(A1)

(A2)

(A1)

(61)

(62)

(61)

(62)

(1)

(2)

(1)

(2)

(A2)

(A1)

(A2)

(A1)

(13)

(14)

(13)

(14)

(1)

(2)

(X2)

F2

F1

(X1)

1

2

1

3

2

1

2

3

2

1

3

2

1

3

2

1

2

11

10

9

3

4

3

2

1

5

2

1

8

7

4

6

14

12

13

8

11

10

9

8

7

6

5

16

15

14

13

12

7

6

5

4

3

2

1

8

7

6

5

4

3

20

19

18

17

26

25

24

23

22

21

1

/1.12

/1.39

DRIVE
RUN

BYPASS
RUN

DRIVE
FAULT

CONTACTS
FOR
CUSTOMER
USE

RATED:
1A, 120VAC
MAX.

AUTO MODE
RUN/STOP
CONTACT
(CLOSED = RUN)

MOTOR #1/MOTOR #2
SELECT CONTACT
(CLOSED=MOTOR #2)
MIN. RATING:

0.1A,120VAC

SMOKE PURGE
CONTACT
(CLOSED=PURGE)
MIN. RATING:

0.1A,120VAC

CUSTOMER
MUST PROVIDE
PROPER
SHORT CIRCUIT
PROTECTION

AND MEANS OF
DISCONNECT.

REMOTE TRANSFER
TO BYPASS CONTACT
(CLOSED=BYPASS)
MIN. RATING:

0.1A,120VAC

100

100

114

114

125

126

- INDICATES CUSTOMER WIRING.

- INDICATES COMPONENTS NOT SUPPLIED BY YASKAWA.

CABINET

BLOWER(S)

(IF REQUIRED)

CABINET

BLOWER(S)

(IF REQUIRED)

JUMPER

JUMPER

MOTOR
OVERLOAD
OR
CUSTOMER
SAFETIES

FAULT

SEE

NOTE 1

J2

J1

FOR INSERTION OF NORMALLY
CLOSED CUSTOMER SAFETY
CONTACTS

FOR INSERTION OF NORMALLY
OPEN BLDG. AUTOMATION SYSTEM
INTERLOCK, OR NORMALLY
OPEN DAMPER END SWITCH

SEE NOTE 3

120VAC DAMPER
SOLENOID 40VA MAX.

INPUT
CONTACTOR

OUTPUT
CONTACTOR

BYPASS
CONTACTOR

MOTOR #1
CONTACTOR

MOTOR #2
CONTACTOR

A

B

208

A

B

(H1)

(H1)

(H1)

(H4)

(H4)

(H2)

NONE

(H2) TO (H4)

(H1) TO (H3)

(H2) TO (H3)

JUMPER

LOCATION

TERMINALS

A3

OPTION D

230/240

460/480

(B)

(B)

(W)

(W)

2 MOTOR

"OR"

OPTION D

MANUAL SPEED POT

OPTION S

2 MOTOR "OR"

OPTION D

120VAC,1 PHASE
100VA MAX. POWER
FOR CUSTOMER USE
CUSTOMER TO
PROVIDE FUSING
(BUSSMANN FNQ-R-1.25
IS RECOMMENDED)

SEE NOTE 6

SEE NOTE 4

MANUAL
SPEED POT
OPTION S

INPUT

VOLTS

CONTROL TRANSFORMER PRIMARY CONNECTIONS

SEE SHEET 2 FOR NOTES AND TABLES.

MA

(R)

(R)

B2,B4,B6

B1,B3,B5

TO A1

TO A1
OR A4

109

112

104

111

128

135

133

138

136

131

138

CONTROL TRANSFORMER

CN206A

BYPASS DRIVE

S201

TEST NORMAL

S203

CN207

HAND

AUTO

CN206B

OFF

S202

PART NUMBER UTC000037-2

DS201

PART NUMBER UOPN0001

CABINET DOOR OPERATOR PANEL

DS206

DS202

CN203

DS205

CN205

DS203

DS204

CN204

CN1

BYPASS OPERATOR

INTERFACE PCB

CONTROL

POWER ON

DRIVE

KEYPAD

SMOKE
PURGE

MOTOR OL/

SAFETIES FAULT

BYPASS

RUN

DRIVE
FAULT

DRIVE

RUN

TO A1
CONTROL BOARD
CN1

R1

POT PCB

MAX. SPEED TRIM

R2

PART NO. URSN0001

2.5K
OHM

MANUAL
SPEED

MANUAL SPEED POT

ASSEMBLY

(1R1)

(1L3)

AUTO

MTR #1

(1R2)

(1L4)

00X

MTR #2

0XX

S104

S105

SMOKE PURGE

REMOTE TRANSFER TO BYPASS

AUTO-TRANSFER TO BYPASS

S103

CN102C

TB1

CN102B

CN103

PG2

PG2

TB1

CN102A

DISABLE

(TOP)

DISABLE

(TOP)

ENABLE

(BOTTOM)

ENABLE

(BOTTOM)

DISABLE

(TOP)

PART NUMBER

UTC000036

ENABLE

(BOTTOM)

BYPASS RELAY

CONTROLLER PCB

PART NUMBER

UTC000036

K3

K2

K3

K1

K2

K5

K4

RC4

RC5

K4

K5

K4

K5

PG2

F6

T1

L2/1.39

EG1

DG1

A3

L11/1.18

L12/1.17

L3/1.14

L4/1.16

L5/1.17

L6/1.18

L7/1.20

L8/1.23

L9/1.24

L1

R1

S1

L13/1.19

A2

124

122

123

121

MC

S1

M4

M3

M2

SN

S5

MA

MA

1L1

1L2

3

100

100

100

116

114

116

114

(R)

111

112

113

115

1

2

(W)

(B)

Items within dashed line boxes are optional equipment

Advertising