Parameters a - 25, Copy function, Auto-tuning – Yaskawa P7B Drive Bypass User Manual

Page 243: Table 1, Parameter list (continued

Advertising
background image

Parameters A - 25

o2-08

Cumulative Operation Time
Selection
Elapsed Time Run

Sets how time is accumulated for the elapsed timer
(o2-07).
0: Power-On Time (Time accumulates whenever Drive

is powered).

1: Running Time (Time accumulates only when Drive is

running)

0 or 1

1

Quick Setting

o2-09

Initialization Specification
Selection
Init Mode Sel

Determines parameter values after a Drive initialization
(A1-03) is executed. This should always be set to "1"
American Spec.
1: American spec
2: European spec
4: PV-A spec
5: PV-E spec

1 to 5

1

Programming

o2-10

Cumulative Cooling Fan
Operation Time Setting
Fan ON Time Set

Sets the initial value of the heatsink fan operation time.

0 to 65535

0H

Programming

o2-12

Fault Trace/Fault History Clear
Function
FLT Trace Init

Clears the fault memory contained in the U2 and U3
monitors.
0: Disabled (no effect).
1: Enabled - resets U2 and U3 monitors, and returns

o2-12 to zero.

0 or 1

0

Programming

o2-14

kWh User Monitor (U1-29)
Initialization
kWH MonitorClear

Used to reset the kilowatt Hour monitor to zero
0: Disabled (no change).
1: Clear all - Resets U1-29 to zero and returns o2-14

to zero.

0 or 1

0

Programming

o2-15

Hand Key Function Selection
Oper Hand Key

Enables or disables the "Hand" key on the digital
operator.
0: Disabled
1: Enabled

0 or 1

1

Programming

COPY Function

o3-01

Copy Function Selection
Copy Function Sel

This parameter controls the copying of parameters to

and from the digital operator.

0: COPY SELECT (no function)
1: INV -> OP READ - All parameters are copied from

the Drive to the digital operator.

2: OP -> INV WRITE - All parameters are copied from

the digital operator into the Drive.

3: OP<-->INV VERIFY - Parameter settings in the

Drive are compared to those in the digital operator.

NOTE: When using the copy function, the Drive
model number and software number (U1-14) must
match or an error will occur.

0 to 3

0

Programming

o3-02

Read Allowed Selection
Read Allowable

Enables and disables all digital operator copy functions.
0: Disabled - No digital operator copy functions are

allowed.

1: Enabled - Copying allowed

0 to 1

0

Quick Setting

Auto-Tuning

T1-02

Motor Rated Power
Mtr Rated Power

Sets the motor rated power in kW.
NOTE: If motor power is given in horsepower, power
in kW can be calculated using the following formula:
kW = Hp * 0.746

0.00 to
650.00

kVA

Dependent

Auto-Tuning

T1-04

Motor Rated Current
Rated Current

Sets the motor rated current. (Used only during an auto-
tune).

kVA

Dependent

kVA

Dependent

Auto-Tuning

Table 1:

Parameter List (Continued

)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Menu

Location

Advertising