All voltages, Specifications c - 4 – Yaskawa P7B Drive Bypass User Manual

Page 258

Advertising
background image

Specifications C - 4

!

All Voltages

Table C.4 Common Drive Specifications

All Models

Specification

Control method

Sine wave PWM

V/f control

Speed range

40:1

Speed control accuracy

±2 to 3% (77

°

F ± 50

°

F) (25

°

C ± 10

°

C)

Frequency accuracy
(temperature characteristics)

Digital references: ± 0.01% (14

°

F to 104

°

F) (-10

°

C to +40

°

C)

Analog references: ±0.1% (77

°

F ± 50

°

F) (25

°

C ±10

°

C)

Frequency setting resolution

Digital references: 0.01 Hz

Analog references: 0.025/50 Hz (10 bit with sign)

Frequency setting signal
(Speed Command)

0-10 Vdc, 4-20 mA

Acceleration/Deceleration
time

0.0 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings)

Main Drive control
functions

Restarting for momentary power loss, bi-directional speed search, overtorque detection, 5 preset speeds,

acceleration/deceleration time changes, S-curve acceleration, 3-wire sequence, auto-tuning, cooling fan ON/OFF con-

trol, torque compensation, jump frequencies, upper and lower limits for frequency references, DC braking for starting

and stopping, high-slip braking, PI control (with sleep function), energy-saving control, Modbus communications (RS-

485/422, 19.2 kbps maximum), fault reset, and copy function

Main Bypass control
functions

Provides an alternate connection for the motor to line power for operation at full speed only, directly from line power.

Three electrically interlocked IEC rated contactors isolate the Drive when operating in Bypass mode. Control logic cir-

cuit provides Hand/Off/Auto functions and safety circuit interlocks. Includes fused 120VAC control transformer, motor

circuit protector/disconnect, motor overload relay, selector switches and indicating lights.

Motor protection

Protection by electronic thermal overload relay

Fuse blown protection

Stops for fuse blown

Overload capacity and
maximum current

110% of rated output current for 60 seconds

Overvoltage protection

208-240VAC: Stops when main-circuit DC voltage is above 410 V

480VAC: Stops when main-circuit DC voltage is above 820 V

Undervoltage protection

208-240VAC: Stops when main-circuit DC voltage is below 190 V

480VAC: Stops when main-circuit DC voltage is below 380 V

Momentary power loss
ride thru

Power Interuptions of 15 ms or more

By selecting the momentary power loss method, operation can be continued if power is restored within 2 s

Cooling fin overheating

Protection by thermistor

Stall prevention

Stall prevention during acceleration, deceleration, or running

Grounding protection

Protection by electronic circuits. (50% of inverter rated current)

Charge indicator

Lit when the main circuit DC voltage is approx. 50 Vdc or more

Enclosure Type

Enclosed wall-mounted type (NEMA 1): CIMR-P7U20P4 thru 2030 and 40P4 thru 4055

Open chassis type (IP00):

CIMR-P7U2022 thru 2110 and 4030 thru 4300

Ambient operating
temperature

14

°

F to 104

°

F (-10

°

C to 40

°

C) NEMA 1 type

14

°

F to 113

°

F (–10

°

C to 45

°

C) Open chassis type

Ambient operating humidity

95% max. (with no condensation)

Storage temperature

68

°

F to 140

°

F (- 20

°

C to + 60

°

C) short-term temperature during transportation

Application site

Indoor (no corrosive gas, dust, etc.)

Altitude

3300 ft. (1000 m), higher altitudes by derate

Vibration

10 to 20 Hz, 32 ft/sec

2

(9.8 m/s

2

) max.; 20 to 50 Hz, 6.5 ft/sec

2

(2 m/s

2

) max.

P

rotectiv

e Fun

ct

ions

Cont

ro

l Char

act

er

is

ti

cs

E

nvi

ronm

en

t

Advertising