Parameter program example – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 112
Advertising

1 Ladder Program Instructions
1.6.3 MOVE BITS Instruction (MOVB)
1-102
Parameter
Program Example
The 10 bits of data starting from MB000000 (bit 0 of MW00000) are transferred to
MB000010 ( bit 0 of MW0000).
Parameter Name
Setting
Source
• Any bit type register
• Any bit type register with subscript
Dest
• Any bit type register (except for # and C registers)
• Any bit type register with subscript (except for # and C regis-
ters)
Width
• Any integer type register
• Any integer type register with subscript
• Constant
After transfer
1
0
0
1
1
0
1
1
0
0
1
0
0
0
0
1
0
0
0
0
0
0
0
1
1
1
0
0
1
0
1
0
1
0
0
1
1
0
1
1
0
0
1
0
0
0
0
1
Transfer range