Parameter program example – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 127
Advertising

1.6 Data Manipulation Instructions
1-117
1
Parameter
Program Example
The word data of MW00000 to MW00009 are transferred to MW00100 to MW00109.
Parameter Name
Setting
Source
• Any integer type register
• Any integer type register with subscript
Dest
• Any integer type register (except for # and C registers)
• Any integer type register with subscript (except for # and C reg-
isters)
Width
• Any integer type register
• Any integer type register with subscript
• Constant
After
transfer
1032H
1133H
1234H
1841H
1032H
1133H
1234H
1841H
1842H
1842H
MW00001
MW00002
MW00008
MW00009
MW00100
MW00101
MW00102
MW00108
MW00109
MW00000
• • •
• • •
• • •
• • •
Advertising