1 Ladder Program Instructions
1.2.23 ASCII CONVERSION 3 Instruction (ASCBIN)
1-54
Program Example
The for-byte ASCII code stored in MW00100 to MW00101 is converted to two-byte binary
data, and the result is stored in MW00200.
ASCBIN
MW00100
MW00200
MW00100
MW00101
MW00200
Source
12H
Upper
34H
Lower
Upper
Lower
32H ('2')
34H ('4')
31H ('1')
33H ('3')