2.2 Trace Functions

2-29

2

Number of Records

The Number of Records is the following.

„

Failure Restoration Data

Failure restoration data is described in Figure 2.10. The number (amount) of restoration data
is stored in SW00093 (ring counter for 1 to 9999).

Fig. 2.10 Failure Restoration Data

„

Readout Data Configuration (Failure Restoration Data)

Data configuration is described in Figure 2.11.

Fig. 2.11 Data Configuration

Minimum number of records

0 (no failure restoration data)

Maximum number of records

64

Failure Restoration Trace Data

Number of
read records

Old

New

User Register

n

Record No. of
read record

Head address of the
register into which
data is read

Readout

Old

New

Dat - Adr 8 words

Record 1

Record 2

Record n

8 words

8 words

Trace data

Time of restoration-old

Time of restoration-new