1 Ladder Program Instructions
1.7.1 DEAD ZONE A Instruction (DZA)
1-120
1.7 DDC Instructions
1.7.1 DEAD ZONE A Instruction (DZA)
Outline
The DZA instruction executes a dead zone operation on integer, double-length integer or
real number data.
The following operation is performed, where Input is the input value, Zone is the designated
dead zone value, and Output is the output value:
• Output
= Input (absolute value of Input is greater than or equal to the absolute value of
Zone)
• Output
= 0 (absolute value of Input is less than the absolute value of Zone)
Format
+D
-D
X
Y
Symbol: DZA
Full Name: Dead Zone A
Category: DDC
Icon: