1 Ladder Program Instructions

1.7.10 INVERSE FUNCTION GENERATOR Instruction (IFGN)

1-148

If the data set in the parameter table for the IFGN instruction are X

n

and Y

n

, the data must be

set so that X

n

≤ Y

n+1

. The IFGN instruction searches for an X

n

/ Y

n

pair within the parame-

ter table for which Y

n

≤ Y ≤ Y

n+1

and computes the output value Y according to the follow-

ing formula:

If the X

n

/ Y

n

pair, which satisfies Y

n

≤ Y ≤ Y

n+1

for an input value Y, does not exist in the

parameter table, the result will be as follows:

• IF X < Y

1

• IF Y > Y

1

Table 1.25 Double-length Integer or Real Type IFGN Instruction Parameters

ADR

Type

Symbol

Name

Specifications

I/O

0

W

N

Number of data

Number of pairs of X and Y

IN

1

W

(Reserved)

Reserved register

IN

2

L/F

X1

Data 1

IN

4

L/F

Y1

Data 1

IN

6

L/F

X2

Data 2

IN

8

L/F

Y2

Data 2

IN

•••

•••

•••

•••

•••

•••

4N-2

L/F

XN

Data N

IN

4N

L/F

YN

Data N

IN

X

n+1

– X

n

X

= X

n

+

Y

n+1

– Y

n

× (Y – Y

n

)

X

2

– X

1

X

= X

1

+

Y

2

– Y

1

( Y – Y

1

)

X

n

– X

n-1

X

= X

n+1

+

Y

n

– Y

n -1

( Y – Y

1

)

X 1 X 2 X

X 3

X 4

Y 1

Y 2

Y

Y 3

Y 4

Ouput value

Input
value