1 Ladder Program Instructions
1.1.1 N.O. Contact Instruction (NOC)
1-4
1.1 Relay Circuit Instructions
1.1.1 N.O. Contact Instruction (NOC)
Outline
The NOC sets the value of the bit output to ON if the value of the referenced register is 1
(ON), and to OFF is the value of the referenced register is 0 (OFF).
Format
Parameter
Program Example
When MW000100 becomes ON, MB000101 becomes ON.
Parameter Name
Setting
Relay No.
• Any bit type register
• Any bit type register with subscript
Symbol: NOC
Full Name: NO Contact
Category: RELAY
Icon:
MB000100
ON
OFF
MB000101
ON
OFF