1 Ladder Program Instructions

1.7.12 LINEAR ACCELERATOR/DECELERATOR 2 Instruction (SLAU)

1-156

Table 1.28 Integer Type SLAU Instruction Parameters

ADR

Type

Symbol

Name

Specifications

I/O

0

W

RLY

Relay I/O

Relay input, relay output

IN/OUT

1

W

LV

100% input level

Scale of the 100% input

IN

2

W

AT

Acceleration time

Time for acceleration from 0% to100% (0.1 s)

IN

3

W

BT

Deceleration time

Time for deceleration from 0% to100% (0.1 s)

IN

4

W

QT

Quick stop time

Time for quick stop from 100% to 0% (0.1 s)

IN

5

W

AAT

S-curve acceleration time

Time spent in the S-curve area during acceleration
(0.01 s)

IN

6

W

BBT

S-curve deceleration time

Time spent in the S-curve area during deceleration
(0.01 s)

IN

7

W

V

Current speed

SLAU output (also output to the A register)

OUT

8

W

DVDT1

Current acceleration/
deceleration speed1
(DVDT1)

Scaled with the normal acceleration rate being set to
5000.

OUT

9

W

(Reserved)

Reserved register

10

W

ABMD

Speed increase upon
holding

Amount of change in speed after hold instruction and
until stabilization.

OUT

11

W

REM1

Remainder

Remainder of acceleration/deceleration rate

OUT

12

W

(Reserved)

Reserved register

13

W

VIM

Remainder

For storage of the previous value of the speed desig-
nation input

OUT

14

L

DVDT2

Current acceleration/
deceleration speed2
(DVDT2)

1000 times of actual acceleration/deceleration

OUT

16

L

DVDT3

Current acceleration/
deceleration speed3
(DVDT3)

Current acceleration/deceleration (

= DCDT2/1000)

OUT

18

L

REM2

Remainder

Remainder of S-curve area acceleration/deceleration
rate

OUT

20

W

REM3

Remainder

Remainder of the current speed

OUT

21

W

DVDTK

DVDT1 coefficient

Scaling coefficient (-32768 to 32767) of current
acceleration/deceleration (DVDT1)

IN