1.7 DDC Instructions

1-133

1

Block Diagram

When the change in deviation output (X-X’) and the previous deviation input (X’)

are the same in sign (diverging) in the differential (D) operation
The divergence differential time (Td1) is used as the differential time.

When the change in deviation output (X-X’) and the previous deviation input (X’)

are opposite in sign (converging) in the differential (D) operation
The convergence differential time (Td2) is used as the differential time.

„

Format

„

Parameter

Parameter Name

Setting

Input

• Any integer type and real number type register
• Any integer type and real number type register with subscript
• Subscript register
• Constant

Parameter

• Register address (except for # and C registers)
• Register address with subscript (except for # and C registers)

Output

• Any integer type and real number type register (except for #

and C registers)

• Any integer type and real number type register with subscript

(except for # and C registers)

• Subscript register

Input

X

Output

Y

LIMIT, DB

+

-

+

+

Td/Ts

Z

-1

K p

Kd

Symbol: PD
Full Name: PD Control
Category: DDC
Icon: