1.7 DDC Instructions

1-133

1

Block Diagram

• When the change in deviation output (X-X’) and the previous deviation input (X’)

are the same in sign (diverging) in the differential (D) operation
The divergence differential time (Td1) is used as the differential time.

• When the change in deviation output (X-X’) and the previous deviation input (X’)

are opposite in sign (converging) in the differential (D) operation
The convergence differential time (Td2) is used as the differential time.

„

Format

„

Parameter

Parameter Name

Setting

Input

• Any integer type and real number type register
• Any integer type and real number type register with subscript
• Subscript register
• Constant

Parameter

• Register address (except for # and C registers)
• Register address with subscript (except for # and C registers)

Output

• Any integer type and real number type register (except for #

and C registers)

• Any integer type and real number type register with subscript

(except for # and C registers)

• Subscript register

Input

X

Output

Y

LIMIT, DB

+

-

+

+

Td/Ts

Z

-1

K p

Kd

Symbol: PD
Full Name: PD Control
Category: DDC
Icon: