1.7 DDC Instructions

1-131

1

1.7.5 PD CONTROL Instruction (PD)

„

Outline

The PD instruction executes a PD control operation according to the contents of a previously
set parameter table. The input (Input) to the PD operation must be integer or real number
data.

Double-length integer data cannot be used. The configurations of the parameter tables for
integer and real number data are different. Operations are performed by processing each
parameter as an integer consisting of the lower-place 16 bits.

* Relay I/O Bit Assignment

Table 1.14 Integer Type PD Instruction Parameters

ADR

Type

Symbol

Name

Specifications

I/O

0

W

RLY

Relay I/O

Relay input, relay output

IN/OUT

1

W

Kp

P gain

Gain of the P offset (a gain of 1 is set to 100)

IN

2

W

Kd

D gain

Gain of the differential circuit input (a gain of 1 is set
to 100)

IN

3

W

Td1

Divergence differential
time

The differential time (ms) used in the case of diverg-
ing input.

IN

4

W

Td2

Convergence differential
time

The differential time (ms) used in the case of con-
verging input.

IN

5

W

UL

Upper PD limit

Upper limit for the P + D offset

IN

6

W

LL

Lower PD limit

Lower limit for the P + D offset

IN

7

W

DB

PD output dead band

Width of the dead band for the P + D offset

IN

8

W

Y

PD output

PD offset output (also output to the A register)

OUT

9

W

X

Input value storage

Storage of the present deviation input value

OUT

BIT

Symbol

Name

Specifications

I/O

0 to 7

(Reserved)

Reserved relay for input

IN

8 to F

(Reserved)

Reserved relay for output

OUT