2 Standard System Function

2.2.4 Inverter Trace Read Function (ITRC-RD)

2-32

„

Parameter

I/O

Definition

Parameter

Name

I/O

Designation

Setting

Input

Execute

B-VAL

Inverter trace read instruction

Abort

B-VAL

Inverter trace read forced interruption instruction

Dev-Typ

I-REG

Type of transmission device

215IF

= 1

MP930

= 4

SVB-01

= 11

Cir-No

I-REG

Line No.

215IF

= 1

MP930

= 1

SVB-01

= 1 to 16

St-No

I-REG

Slave station No.

215IF

= 1 to 64

MP930

= 1 to 14

SVB-01

= 1 to 14

Ch-No

I-REG

Transmission buffer channel No. (No designation)

215IF

= 1 to 3

MP930

= 1

SVB-01

= 1 to 8

Rec-Size

I-REG

Number of records to be read (1 to 64)

Select

I-REG

Items to be read (0001H to FFFFH)
Bits 0 to F correspond to trace data items 1 to 26

Dat-Adr

Address in-
put

Head address of data buffer register (address of MW or DW)

Output

Busy

B-VAL

The reading of inverter trace data is in progress.

Complete

B-VAL

Completion of inverter trace read

Error

B-VAL

Occurrence of error

Status

I-REG

Inverter trace read execution status

Rec-Size

I-REG

Number of read records

Rec-Len

I-REG

Length of read record (for 1 record)

Table 2.14 Configuration of the Inverter Trace Read Execution Status (STATUS)

Name

Bit No.

Remarks

System reserved

bit0 to bit8

Transmission parameter
error

bit9

The function will not be executed.

System reserved

bit10

Error in the designated
number of records

bit11

The function will not be executed.

Data storage error

bit12

The function will not be executed.

Transmission error

bit13

The function will not be executed.

System reserved

bit14

Address input error

bit15

The function will not be executed.