2 Standard System Function

2.1.2 Receive Message Function (MSG-RCV)

2-16

Status (PARAM01)

Output the status of the transmission unit. See "Status (PARAM01)" (on page 2-5) for
details.

Called Station Number (PARAM02)

The station number of sending side is output.

Function Code (PARAM04)

Output the MEMOBUS function code received. Refer to Table 2.8.

Note: 1.

−: cannot be output, OK: can be output

2. The MB, MW, IB, and IW registers can be used respectively as the

coil, holding register, input relay, and input registers during slave
operation.

Table 2.8 Function Codes

Function Code

Setting

00H

Unused

01H

Read coil status

OK

02H

Read input relay status

OK

03H

Read contents of holding register

OK

04H

Read contents of input register

OK

05H

Change status of single coil

OK

06H

Write into a single holding register

OK

07H

Unused

08H

Loop-back test

OK

09H

Read contents of holding register (expanded)

OK

0AH

Read contents of input register (expanded)

OK

0BH

Write into holding register (expanded)

OK

0CH

Unused

0DH

Discontinuous readout of holding register (expanded)

OK

0EH

Discontinuous write into holding register (expanded)

OK

0FH

Change status of a multiple coil

OK

10H

Write into a plurality of holding register

OK

11H to 20H

Unused

21H to 3FH

System reserved

40H to 4FH

System reserved

50H to

Unused